DL-PT202D Voltage Transformer
Flame retardant properties:UL94-V0
Insulation resistance:Normal than 1000MΩ
Work voltage:0.66/0.72kV
Compressive strength:3.5kV/50Hz/1min
Work frequency:50/60Hz
Operating temperature:-40℃~+85℃
Used for:Voltage isolation measurement,power compensation,microcomputer protection
Installation method:PCB in-line
Dimension ( in mm):
Front view Bottom view Electrical diagram
Technical Data:
|
DL-PT202D |
Unit |
Rated input |
2 |
mA(AC) |
Rated output |
2 |
mA(AC) |
Rated sampling load |
500 |
Ω |
Rated sampling voltage |
1 |
V(AC) |
Turns ratio |
1000/1000 |
—— |
Rated Phase shift |
≤8(RL=0Ω) |
' |
Accuracy |
0.1 |
Level |
Linearity |
0.1 |
% |
Maximum input |
0~8(RL≤125Ω) |
mA(AC) |
Applicable voltage |
0~1000 |
V(AC) |
DCR |
113±10 |
Ω |
Weight |
14.1 |
g |
Working principle:A current-limiting resistor R is connected in series at the input terminal to convert the measured voltage into a current of about 2mA and input to the transformer,then the transformer outputs a current of about 2mA in ratio 1/1,,and finally a sampling resistor R' is connected in parallel at the output terminal of the transformer and gets an output voltage。